P15FE
1B9804 - P15FEInformation saved in
DME
Fault code
1B9804 - P15FE
Fault text
Engine switch-off time, signal: no signal
Fault description
The diagnostic function monitors transmission of the CAN
time signal from the instrument cluster. Diagnosis is
interlocked by CAN fault.
Condition for fault identification
Test condition:
The fault is recognized when no CAN time signal is
transmitted for longer than 5 sec.
Potential problem source(s):
- Collateral fault resulting from fault memory entries in the
DME and/or instrument cluster
Terminal condition: Terminal 15
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory
immediately.
Action in service
- Because this is a collateral fault, start by resolving issues
related to other faults logged in the DME or instrument
cluster; no additional action will be needed with these kinds
of faults
Fault effect and breakdown warning
Breakdown notice:
None
Possible apparent symptoms:
No display of time and date
Driver information
Warning light:
- ECE emissions warning lamp: on
- ECE electronic engine power reduction: on
- CC message: on
- US emissions warning lamp: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
None