P0A15
219002 - P0A15Information saved in
DME
Fault code
219002 - P0A15
Fault text
Active engine mount, electric: short circuit to ground
Fault description
The diagnostic function monitors the wire from the DME to
the engine mount for shorts to ground.
Condition for fault identification
Test condition:
The fault is recognized when a short circuit to ground is
present.
Potential problem source(s):
- Defect in wiring harness between engine mount and DME
- Defective engine mount
- Defective DME
Terminal condition: none
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Engine on
- Engine speed > 1200 rpm,
- Vehicle speed > 8.8 km/h
Condition for fault memory entry
This fault is logged in the control module's fault memory
immediately.
Action in service
- Check wiring harness between DME and engine mount
- Replace engine mount
- Replace DME
Fault effect and breakdown warning
Breakdown notice:
None
Possible apparent symptoms:
None
Driver information
Warning light:
- ECE emissions warning lamp: off
- ECE electronic engine power reduction: off
- CC message: none
- US emissions warning lamp: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
None