1F1A80
1F1A80 - P16EAInformation saved in
DME
Fault code
1F1A80 - P16EA
Fault text
DME, internal fault, watchdog output: malfunction
Fault description
The diagnostic function monitors the internal ABE and
WDA wire in the DME.
Condition for fault identification
Test condition:
The fault is recognized by the self-diagnosis.
Potential problem source(s):
- DME defective
Terminal condition: Terminal 15
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory
immediately.
Action in service
- Only replace the DME if the fault remains present
continuously or if the fault frequency is greater than 3
Fault effect and breakdown warning
Breakdown notice:
Continued driving is not possible while fault is active. When
the fault is no longer present continued driving is possible
with no restrictions.
Possible apparent symptoms:
- Non-starter in extreme cases
Driver information
Warning light:
MY10 ECE:
- ECE emissions warning lamp: on
- ECE electronic engine power reduction: on
- CC message: on
MY10 US:
- US emissions warning lamp: off
- US electronic engine power reduction: on
- CC message: on
Service instruction
- A terminal status switch must be conducted before this
fault can be deleted.