65 50 170 Replacing the Cover For the Central Information Display (CID) (As of 10/2009)
65 50 170 Replacing The Cover For The Central Information Display (CID) (as Of 10/2009)
Special tools required:
IMPORTANT: Read and comply with notes on protection against electrostatic damage (ESD protection).
Necessary preliminary work:
- Remove Central Information Display
Release screws (1).
Tightening torque: 65 50 2AZ
NOTE: To tighten screws, use special tool 00 9 460.
IMPORTANT: Risk of damage.
Carefully unlock latch mechanisms (1) with a suitable tool. Remove cover (2) from Central Information Display (3).
IMPORTANT: Before/after assembly, cover is bolted to the Central Information Display, correct installation position must first be checked.
Installation note:
Before connecting the screw connection, check whether latch mechanisms marked with an arrow are correctly seated.
Installation note:
Before connecting the screw connection, check all-round rim at the places marked with an arrow.