P2442
27B1 - P2442Information saved in
DME
Fault code
27B1 - P2442
Fault text
Secondary air-injection system flow rate, Bank 2
Fault description
Condition for fault identification
Test condition:
Continuous compliance with secondary air-injection system
conditions
Terminal condition: Engine running
Voltage condition:
ub > K_DIAG_TR_Plus_Min
Condition for fault memory entry
sls_obdh_mdf_max_intg_norm (following end of secondary
air system operation) >
K_Sekund�rluftsystem_OBDH_Sekund�rluftventil_Max
sls_obdh_lam_asv_intg_norm above threshold
Action in service
1. Perform system test
2. Replace shutoff valve as indicated
Fault effect and breakdown warning
MIL is on after 2x engine cold start
Driver information
Warning light:
No
Service instruction
none