P0430
278A - P0430Information saved in
DME
Fault code
278A - P0430
Fault text
Conversion rate of Bank 2 catalytic converter
Fault description
Condition for fault identification
Test condition:
Oxygen load - Forced stimulation with pulse stroke is
active: * Engine temperature > K_O2_OBD_TMOT) *
Engine rom with range (K_O2_OBD_N_Max
u.K_O2_OBD_N_Min)
* Relative induction charge density within range
(K_O2_OBD_Rf_Max u.K_O2_OBD_RF_Min) * Catalytic
converter temperature within range
Terminal condition: Engine running -
idle or partial load
Voltage condition:
none
Condition for fault memory entry
Diagnosis value above the threshold
K_Kat_OBD_WERT_Max
Action in service
1. Check exhaust system for leaks /2. No faults related to
oxygen sensor or fuel system or VANOS should be present
/3. Conduct oxygen sensor test routines, even if no oxygen
sensor fault is present./ 4. Replace catalytic conveter near
engine
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
No
Service instruction
none