2B29 - P16B8 (DME)
2B29 - P16B8Information saved in
DME
Fault code
2B29 - P16B8
Fault text
Torque manager monitoring
Fault description
Condition for fault identification
Test condition:
Engine speed greater than K_MD_SK_N_MDMin and
starting torque dissipated
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
Minimum torque greater than K_MD_SK_Max_MDMin
Action in service
1. Delete stored DTCs from error memory
2. Update DME
3. Replace DME
Fault effect and breakdown warning
Engine speed limited to 7000 rpm / Check Control message /
power reduction / MIL comes on after engine runs 2x
Driver information
Warning light:
No
Service instruction
none