2B1B - P1374 (DME)
2B1B - P1374Information saved in
DME
Fault code
2B1B - P1374
Fault text
Ionic current signal amplification for Bank 2
Fault description
Condition for fault identification
Test condition:
none
Terminal condition: none
Voltage condition:
9 V
Condition for fault memory entry
ATIC29 driver diagnosis
Action in service
1. Check plug and wiring harness at ionic current control
module
2. Replace ionic current control module as indicated
Fault effect and breakdown warning
No symptoms apparent to driver, possible reduction in
power
Driver information
Warning light:
No
Service instruction
none