Condition For Fault Memory Entry - nZiel
2B11 - P0700Information saved in
DME
Fault code
2B11 - P0700
Fault text
SMG speed monitoring
Fault description
Condition for fault identification
Test condition:
during shift execution,
otherwise
Terminal condition: Terminal 87
Voltage condition:
min (ub,u_wakeup) > K_SMG_CAN
_ED_Plus_Min
Condition for fault memory entry
nZiel > K_SMG_SK_NMax_Fehlerspeicher
nZiel > n_begr + Offset
Action in service
1. Read out DTCs from SMG ECU and then delete / 2. Read
out DTCs from DME ECU and then delete / 3. Use vehicle
tester to repair all active component errors (in DME ECU
and SMG ECU) / 4. If DTC is entered again: Use vehicle
tester to repair CAN error
Fault effect and breakdown warning
Engine speed limitation displayed / Check Control message /
power reduction
Driver information
Warning light:
No
Service instruction
none