278B - P104B (DME)
278B - P104BInformation saved in
DME
Fault code
278B - P104B
Fault text
Control activation of VANOS pressure accumulator valve
Fault description
Condition for fault identification
Test condition:
none
Terminal condition: Terminal 87 on
Voltage condition:
ub > K_ED_PlusMin
Condition for fault memory entry
Driver diagnosis ATIC35
(voltage too high with valve off)
Action in service
1. Check plug and wiring harness at pressure accumulator
valve
2. Replace pressure accumulator valve
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
No
Service instruction
none