P3259
200904 - P3259Information saved in
DME
Fault code
200904 - P3259
Fault text
DME, internal fault, monitoring fuel quantity: operating
mode in rel. to lambda implausible
Fault description
Fuel quantity monitoring function
Condition for fault identification
Test condition:
Control module monitor
Throttle valve is not without current;
operating mode implausible relative to lambda
Terminal condition: Terminal 15
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
5 sec.
Action in service
Check paths for O2 sensors, fuel and air
If frequency is > 3 Replace DME
Fault effect and breakdown warning
none
none
Driver information
Warning light:
MIL OFF EML ON CC: Reduced power, engine
malfunction
RPM limited to 1300 rpm
Service instruction
- Data configured