P10DD
CD8408 - P10DDInformation saved in
DME
Fault code
CD8408 - P10DD
Fault text
FlexRay data bus: Hardware faulty
Fault description
The diagnostic function monitors the FlexRay controller
Condition for fault identification
Test condition:
The fault is recognized when a hardware defect is detected
Potential problem source(s):
- Defect in FlexRay controller
Terminal condition: Terminal 15
Voltage condition:
Voltage in onboard electrical system > 10 V
Temperature condition:
None
Time condition:
- 750 sec.
Other conditions:
None
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 0.06 sec.
Action in service
Replace DME if the fault is present permanently, or
sporadically with a fault frequency greater than 3.
Fault effect and breakdown warning
Breakdown notice:
None
Possible apparent symptoms:
- none
Driver information
Warning light:
MY10:
- ECE emissions warning lamp: off
- ECE electronic engine power reduction: off
- CC message: none
MY11:
- ECE emissions warning lamp: off
- US emissions warning lamp: on
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: One
Service instruction
- none