10F102 - P029A (DME)
10F102 - P029AInformation saved in
DME
Fault code
10F102 - P029A
Fault text
Cylinder equalization above lambda, cylinder 1: cylinder-
selective oxygen-sensor control, upper limit reached
Fault description
The diagnostic function monitors the lambda at the
individual cylinders.
Condition for fault identification
Test condition:
The fault is recognized when the mixture for one cylinder
must be corrected by more than +/- 15 %.
Potential problem source(s):
- Defective injector
- Oxygen sensor defective
- Fuel pressure fluctuates or is consistently too high or too
low
- Defective wastegate control
- Exhaust backpressure too high
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- from - 10 °C to normal operating temperature
Time condition:
- None
Other conditions:
- v > 90 km/h
- Highest gear
- Constant driving
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 60 sec.
Action in service
- If diagnostic fault codes related to the oxygen sensor,
catalytic converter or fuel system are present, repair these
- Check fuel pressure
- Check wastegate control
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- Engine runs poorly
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: off
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
- none