P0003
11C402 - P0003Information saved in
DME
Fault code
11C402 - P0003
Fault text
Fuel-supply control valve, activation: short circuit to ground
Fault description
The diagnostic function monitors the flow-control valve's
PWM control signal's upper lower value.
Condition for fault identification
Test condition:
The fault is recognized when the PWM signal at the flow-
control valve is < 1.5 %.
Potential problem source(s):
- Signal wire is shorted to ground
Terminal condition: Terminal 15
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory if
it remains present for longer than 0.5 sec.
Action in service
- Check wiring harness to flow-control valve in the high-
pressure pump
- Replace high-pressure pump
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none
Driver information
Warning light:
- ECE emissions warning lamp: on
- US emissions warning lamp: on
- ECE electronic engine power reduction: on
- US electronic engine power reduction: on
- CC message: on
Service instruction
- none