Manufacturer Code Charts: 190504
190504 - P240AInformation saved in
DME
Fault code
190504 - P240A
Fault text
DMTL, heating, activation: open circuit
Fault description
The diagnostic function monitors the electrical connection
between the DME and the DMTL heater.
Condition for fault identification
Test condition:
The fault is recognized when a control signal is transmitted
to the DMTL heater and an open circuit is present.
Potential problem source(s):
- Defect in wiring harness
- Defect in power supply to DMTL
- DMTL defective
Terminal condition: none
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- 5 sec.
Other conditions:
- none
Condition for fault memory entry
The fault is logged in the fault memory if it remains
continuously present for longer than 5 sec.
Action in service
- Check wiring harness
- Check voltage supply to DMTL
- Replace DMTL
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- none
Driver information
Warning light:
- ECE emissions warning lamp: off
- US emissions warning lamp: on
- ECE electronic engine power reduction: off
- US electronic engine power reduction: off
- CC message: off
Service instruction
- On E7X versions the power-supply voltage is from
Terminal 30gz, which is controlled by the CAS. If the
battery is severely discharged the CAS may deactivate this
Terminal 30gz, leading to this diagnostic fault code entry.