102801 - P116C (DME)
102801 - P116CInformation saved in
DME
Fault code
102801 - P116C
Fault text
Air-mass sensor, measurement range: signal outside valid
range
Fault description
Air-mass sensor, measurement range
Condition for fault identification
Test condition:
Engine start completed
Terminal condition: Terminal 15
Voltage condition:
OBD1 conditions met (voltage between 10 V and 16 V)
Condition for fault memory entry
0.2 sec.
Action in service
1) Visual inspection of plug-in contacts (at both component
and DME ends)
2) Measure sensor wire, power supply and ground (possible
intermittent contact!)
3) Replace sensor
Fault effect and breakdown warning
none
none
Driver information
Warning light:
MIL ON
Service instruction
- Data configured