24 14 001 Replacing Selector Shaft Seal (GA6HP26Z/6HP32Z)
24 14 001 - Replacing selector shaft seal (GA6HP26Z/6HP32Z)
Special tools required:
Important!
After completion of work, check transmission fluid level 00 11 500 Checking/Topping Up Fluid Level In Automatic Transmission (GA6HP26Z/GA6HP32Z).
Use only the approved transmission fluid.
Failure to comply with this requirement will result in serious damage to the automatic transmission!
Necessary preliminary tasks:
Remove underbody protection.
E65/M67TU only
Release screws.
Remove transmission underguard (1).
Remove left diesel particulate filter.
E65/N62 only:
Release screws.
Remove transmission underguard (1).
Remove left oxygen sensor.
E60/ E63/ E64, N62 only:
Remove rear underbody protection.
Remove left oxygen sensor (N62 only).
Note:
Version 1:
Unfasten nut.
Remove cable (1).
Installation Note:
Adjusting cable:
- Release nut
- Adjust cable by means of holder (2)
Distance A ≥ 1 mm.
Note:
Version 2:
Grip clamping sleeve (1) and slacken nut (2).
Tightening torque 25 16 2AZ [1][2]Shifter A/T.
Detach retainer (3) towards bottom using a screwdriver.
Pull cable (4) out of holder.
Installation Note:
Adjust selector lever Adjustments.
Note:
Version 3:
Release shift cable head (2) from ball head.
Installation Note:
Adjust selector lever.
Illustration similar.
Unfasten nut.
Take off holder (1).
Tightening torque 24 51 1AZ [1][2]Shift Linkage, A/T.
Note:
Illustration shows E65.
Screw in special tool 24 5 361 until it is firmly connected with shaft seal.
Screw special tool 24 5 362 onto special tool 24 5 361 and tighten down.
This pulls the shaft seal out of the transmission housing.
Oil sealing lip on shaft seal (1).
Screw in shaft seal (1) with special tools 24 5 366 and 24 5 364 as far as it will go.