49A3 - U0155 (DDE)
49A3 - U0155Information saved in
DDE
Fault code
49A3 - U0155
Fault text
DDE: Message (outside temperature, 0x310): Message from
instrument cluster failed
Fault description
If the message A_TEMP_RELATIVZEIT is not received
the diagnostic trouble code is logged.
Condition for fault identification
Test condition:
The following conditions must be satisfied:
- The message must be active.
- Terminal 15 must be active.
The signals are transmitted in cycles with a periodicity of
1000 ms.
The error is checked in a 100 ms time grid.
Voltage condition:
The following conditions must be satisfied:
- The message must be active.
- Terminal 15 must be active.
The signals are transmitted in cycles with a periodicity of
1000 ms.
The error is checked in a 100 ms time grid.
Condition for fault memory entry
Debounce (6000 ms)
Action in service
Conduct CAN system analysis.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none