U0106
49A5 - U0106Information saved in
DDE
Fault code
49A5 - U0106
Fault text
LIN bus, communication:
Fault description
Monitoring LIN communications with glow-plug preheating
control module. The diagnostic trouble code is logged if no
LIN bus communications with the glow-plug preheating
control module are possible.
Condition for fault identification
Test condition:
The test routine is executed continuously every 100 ms.
Voltage condition:
The test routine is executed continuously every 100 ms.
Condition for fault memory entry
Debounce (1200 ms)
Action in service
Check LIN bus.
If LIN bus is OK:
Replace glow-plug preheating control module.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none