4B3A - P229F (DDE)
4B3A - P229FInformation saved in
DDE
Fault code
4B3A - P229F
Fault text
DDE: Nitrogen oxide sensor downstream of SCR catalytic
converter, short circuit to ground: Short circuit to ground
Fault description
The diagnostic trouble code is logged when the signal from
the NOs sensor behind the SCR converter falls below the
limit 0.
Condition for fault identification
Test condition:
The test routine is executed when a valid linear lambda
signal has been received.
Voltage condition:
The test routine is executed when a valid linear lambda
signal has been received.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace NOx sensor 2 (behind SCR converter).
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none