4061 - P2228 (DDE)
4061 - P2228Information saved in
DDE
Fault code
4061 - P2228
Fault text
DDE: Ambient-pressure sensor (installed in control unit),
signal: Open or short circuit to ground
Fault description
Barometric pressure sensor monitoring function. The
diagnostic trouble code is logged when the raw sensor signal
(voltage) is less than 1110 mV.
Condition for fault identification
Test condition:
-
Voltage condition:
-
Condition for fault memory entry
Debounce (50 ms)
Action in service
Replace DDE control module.
Fault effect and breakdown warning
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Driver information
Warning light:
MIL
Service instruction
none