4D11 - P20EE (DDE)
4D11 - P20EEInformation saved in
DDE
Fault code
4D11 - P20EE
Fault text
Reduction agent metering, long-term adaptation: Adaptation
value too high
Fault description
Monitoring long-term adaptation factor. The diagnostic
trouble code is logged when the long-term adaptation factor
rises above the maximum limit 1.
Condition for fault identification
Test condition:
The error check runs only with a rising flank for long-term
adaptation factor and when no other faults are present.
The check runs continuously in a 100 ms grid.
Voltage condition:
The error check runs only with a rising flank for long-term
adaptation factor and when no other faults are present.
The check runs continuously in a 100 ms grid.
Condition for fault memory entry
Event debounced (10)
Action in service
Depending upon the problem source:
- Refill tank (quality of reduction agent).
- Clean/replace (metering module/NOx sensor/SCR
converter/particulate filter).
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none