47F4 - P2064 (DDE)
47F4 - P2064Information saved in
DDE
Fault code
47F4 - P2064
Fault text
DDE: Reducing-agent metering valve, activation: Negative
side, short circuit to positive
Fault description
The DDE recognizes a short circuit to positive error in the
output stage:
Metering module.
Condition for fault identification
Test condition:
The error check proceeds continuously according to the
programmed process grid.
Voltage condition:
The error check proceeds continuously according to the
programmed process grid.
Condition for fault memory entry
Debounce (1000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
3. Use diagnostic system to check metering module.
4. Replace metering module.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none