FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

4153 - P200A (DDE)

4153 - P200A

Information saved in
DDE

Fault code
4153 - P200A

Fault text
DDE: Swirl-flap actuator, activation: Output stage,
overtemperature

Fault description
The DDE recognizes an over-temperature fault in the output
stage:
Swirl-valve actuator.

Condition for fault identification
Test condition:
The check frequency depends on the process sequence
control.
Voltage condition:
The check frequency depends on the process sequence
control.

Condition for fault memory entry
Debounce (220 ms)

Action in service
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling
are OK:
Replace DDE control module.

Fault effect and breakdown warning
-

Driver information
Warning light:
MIL

Service instruction
none