486C - P124E (DDE)
486C - P124EInformation saved in
DDE
Fault code
486C - P124E
Fault text
NOx sensor after DeNOx cat', plausibility:
Fault description
Monitoring of correction factors for NOx sensor behind
SCR converter.
The diagnostic trouble code is logged when:
- the NOx correction factor (gradient) does not lie between
800 and 1200.
- the NOx correction factor (offset) does not lie between -
200 and 200.
Condition for fault identification
Test condition:
The error check runs while the sensor is being initialized.
Voltage condition:
The error check runs while the sensor is being initialized.
Condition for fault memory entry
Debounce (500 ms)
Action in service
Replace NOx sensor behind SCR converter.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none