4A7F - P0670 (DDE)
4A7F - P0670Information saved in
DDE
Fault code
4A7F - P0670
Fault text
DDE: Glow control unit internal: internal EEPROM fault
Fault description
EEPROM error in glow-plug preheating control module.
The DDE recognizes the fault based on a LIN signal.
The LIN signal can assume the following values:
- Fault in EEPROM
- Invalid
Condition for fault identification
Test condition:
The LIN message is transmitted every 500 ms.
Voltage condition:
The LIN message is transmitted every 500 ms.
Condition for fault memory entry
Debounce (1200 ms)
Action in service
Replace glow-plug preheating control module.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none