4C1F - P0611 (DDE)
4C1F - P0611Information saved in
DDE
Fault code
4C1F - P0611
Fault text
DDE: DDE control unit internal: Injectors, bank 2, fault in
activation module
Fault description
The internal monitoring function detects a chip error in the
injectors' activation module.
Condition for fault identification
Test condition:
The error check is implemented once per camshaft rotation.
Voltage condition:
The error check is implemented once per camshaft rotation.
Condition for fault memory entry
Event debounced (10)
Action in service
Replace DDE control module.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL_SVS
Service instruction
none