4986 - P0545 (DDE)
4986 - P0545Information saved in
DDE
Fault code
4986 - P0545
Fault text
DDE: Exhaust backpressure sensor before catalytic
converter, signal: Short circuit to ground
Fault description
Pre-oxidation catalyst temperature sensor monitoring
function. When the raw sensor signal (voltage) is less than
the minimum the diagnostic trouble code is logged.
Condition for fault identification
Test condition:
The error check proceeds continuously according to the
programmed process grid.
Voltage condition:
The error check proceeds continuously according to the
programmed process grid.
Condition for fault memory entry
Debounce (600 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Exhaust-gas temperature sensor before oxidation catalyst.
Fault effect and breakdown warning
The error disables regeneration in the particulate filter.
Driver information
Warning light:
MIL
Service instruction
none