4B39 - P0403 (DDE)
4B39 - P0403Information saved in
DDE
Fault code
4B39 - P0403
Fault text
DDE: Exhaust-gas recirculation controller, activation: Open
circuit
Fault description
The DDE recognizes an open circuit in the output stage:
EGR actuator.
Condition for fault identification
Test condition:
The error is evaluated when a sticking valve is recognized or
the open circuit diagnosis is active.
The diagnosis routine also runs when a start occurs.
Voltage condition:
The error is evaluated when a sticking valve is recognized or
the open circuit diagnosis is active.
The diagnosis routine also runs when a start occurs.
Condition for fault memory entry
Debounce (220 ms)
Action in service
1. Check wires and plug connections.
(open circuit)
2. If wiring and plug connections are OK:
Replace EGR actuator.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL_SVS
Service instruction
With some engine versions the appropriate service function
must be used to reset the EGR valve's adaptation before the
EGR valve is replaced.