P0192
3F31 - P0192Information saved in
DDE
Fault code
3F31 - P0192
Fault text
DDE: Rail-pressure sensor, signal: Short circuit to ground
Fault description
Rail-pressure sensor monitoring function. The diagnostic
trouble code is logged when the raw sensor signal (voltage)
is less than 256 mV.
Condition for fault identification
Test condition:
The monitoring functions are only performed when no
sensor power-supply fault diagnostic trouble code has been
logged.
The test routine is executed continuously in a 10 ms grid.
Voltage condition:
The monitoring functions are only performed when no
sensor power-supply fault diagnostic trouble code has been
logged.
The test routine is executed continuously in a 10 ms grid.
Condition for fault memory entry
Debounce (140 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace rail-pressure sensor.
Fault effect and breakdown warning
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Driver information
Warning light:
MIL_SVS
Service instruction
none