435A - P0182 (DDE)
435A - P0182Information saved in
DDE
Fault code
435A - P0182
Fault text
DDE: Fuel-temperature sensor, range: upper physical limit
exceeded
Fault description
The diagnostic trouble code is logged when the physical
sensor signal for fuel temperature rises above the limit value
100 �C.
Condition for fault identification
Test condition:
The monitoring routine is executed only provided that no
electrical errors have been logged. The error check proceeds
continuously in the programmed process grid.
Voltage condition:
The monitoring routine is executed only provided that no
electrical errors have been logged. The error check proceeds
continuously in the programmed process grid.
Condition for fault memory entry
Debounce (4000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace fuel pressure and temperature sensor (on vehicles
without closed-loop control of low-pressure fuel-delivery
circuit: fuel-temperature sensor).
Fault effect and breakdown warning
Proceed to the nearest BMW Service facility.
Driver information
Warning light:
MIL
Service instruction
none