436A - P007C (DDE)
436A - P007CInformation saved in
DDE
Fault code
436A - P007C
Fault text
DDE: Charge-air temperature sensor, range: upper physical
limit exceeded
Fault description
The diagnostic trouble code is logged when the sensor signal
for boost-air temperature rises above the limit value 110 �C.
Condition for fault identification
Test condition:
The monitoring function is only implemented when no
sensor power-supply problem is logged.
Voltage condition:
The monitoring function is only implemented when no
sensor power-supply problem is logged.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace charge-air temperature sensor.
Fault effect and breakdown warning
Proceed to the nearest BMW Service facility.
Driver information
Warning light:
MIL
Service instruction
none