P0035
46D5 - P0035Information saved in
DDE
Fault code
46D5 - P0035
Fault text
DDE: Compressor bypass plate, activation: Short circuit to
positive
Fault description
The DDE recognizes a short circuit to positive in the output
stage: Switch valve for compressor bypass valve.
Condition for fault identification
Test condition:
The test routine is implemented each time process runs.
Voltage condition:
The test routine is implemented each time process runs.
Condition for fault memory entry
Debounce (220 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace switch valve for compressor bypass valve.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL_SVS
Service instruction
none