P0033
46D7 - P0033Information saved in
DDE
Fault code
46D7 - P0033
Fault text
DDE: Compressor bypass plate, activation: Open circuit
Fault description
The DDE recognizes an open-circuit error at the output
stage: switch valve for compressor bypass valve.
Condition for fault identification
Test condition:
The test routine is implemented each time process runs.
Voltage condition:
The test routine is implemented each time process runs.
Condition for fault memory entry
Debounce (220 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace switch valve for compressor bypass valve.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL_SVS
Service instruction
none