P0032
4205 - P0032Information saved in
DDE
Fault code
4205 - P0032
Fault text
DDE: Oxygen sensor, heater activation: Short circuit to
positive
Fault description
The DDE recognizes a short circuit to positive in the output
stage:
Oxygen sensor heating.
Condition for fault identification
Test condition:
The following conditions must be present for the error
check:
- The diagnostic function must be active.
- The pre-debounced battery voltage must be greater than
10700 mV.
Voltage condition:
The following conditions must be present for the error
check:
- The diagnostic function must be active.
- The pre-debounced battery voltage must be greater than
10700 mV.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace oxygen sensor.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none