4D5C
4D5C - P242CInformation saved in
DDE
Fault code
4D5C - P242C
Fault text
Exhaust gas temperature sensor before SCR cat, plausibility:
upper physical limit exceeded
Fault description
When the physical sensor signal for exhaust-gas temperature
before the SCR converter rises above the limit value 750 �C
the diagnostic trouble code is logged.
Condition for fault identification
Test condition:
The monitoring function is only implemented when no
electrical error is logged.
Voltage condition:
The monitoring function is only implemented when no
electrical error is logged.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace exhaust-gas temperature sensor before the SCR
converter.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none