4C50
4C50 - P041BInformation saved in
DDE
Fault code
4C50 - P041B
Fault text
DDE: Temperature sensor after low-pressure exhaust-gas
recirculation cooler, plausibility: Temperature after low-
pressure exhaust-gas recirculation cooler not plausible in rel.
to remaining temperature signals
Fault description
The measured variables from the air-temperature sensors are
checked against each other for relative plausibility. The
DTC is logged when the exhaust-gas temperature
downstream from the low-pressure EGR cooler is
implausible relative to all of the other measured values.
Condition for fault identification
Test condition:
The monitoring routine executes once per driving cycle in
the cold-start phase.
Voltage condition:
The monitoring routine executes once per driving cycle in
the cold-start phase.
Condition for fault memory entry
Debounce (50 ms)
Action in service
Replace exhaust-gas temperature sensor downstream from
low-pressure EGR cooler.
Fault effect and breakdown warning
Proceed to the nearest BMW Service facility.
Driver information
Warning light:
MIL
Service instruction
none