4C09
4C09 - P042AInformation saved in
DDE
Fault code
4C09 - P042A
Fault text
Exhaust-gas temperature sensor before particulate filter,
plausibility: Difference, measured from calculated exhaust-
gas temperature before particulate filter, too high
Fault description
The DTC is logged when the difference between the
measured and the simulated exhaust-gas temperature
upstream from the particulate filter lies outside a plausibility
window.
Condition for fault identification
Test condition:
The error check is activated when no other faults are stored
for the sensor.
Voltage condition:
The error check is activated when no other faults are stored
for the sensor.
Condition for fault memory entry
Debounce (60000 ms)
Action in service
Replace pre-particulate filter exhaust-gas temperature
sensor.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
Exhaust-gas temperature sensor before particulate filter
defective.