4BA0
4BA0 - P0113Information saved in
DDE
Fault code
4BA0 - P0113
Fault text
DDE: Intake-air temperature sensor, signal: Open or short
circuit to positive/ground or temperature too high
Fault description
The diagnostic trouble code is logged when the intake-air
temperature sensor signal rises above the limit value 130 �C.
Condition for fault identification
Test condition:
The monitoring function is only implemented when no
sensor power-supply problem is logged.
Voltage condition:
The monitoring function is only implemented when no
sensor power-supply problem is logged.
Condition for fault memory entry
Debounce (1000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace mass-airflow sensor.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none