4AEE
4AEE - P062FInformation saved in
DDE
Fault code
4AEE - P062F
Fault text
DDE: DDE control unit internal (EEP): EEP error when
writing
Fault description
The diagnostic trouble code is logged when more than 3
write errors occur during attempts to write a block to the
storage medium (EEPROM).
Condition for fault identification
Test condition:
Each time the storage medium is accessed for reading.
Voltage condition:
Each time the storage medium is accessed for reading.
Condition for fault memory entry
-None, if debounce is defined as a constant 3.
Action in service
Replace DDE control module.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none