4ABB
4ABB - P042AInformation saved in
DDE
Fault code
4ABB - P042A
Fault text
Exhaust-gas temperature sensor before particulate filter,
plausibility: Exhaust temperature before particulate filter not
plausible when compared to the other exhaust temperature
signals
Fault description
Plausibility check on exhaust-gas temperature sensor before
the particulate filter. For the plausibility check the exhaust-
gas temperature value before the particulate filter is
compared with the other exhaust-gas temperature data, then
sensor plausibility is determined by calculating the
differences.
The diagnostic trouble code is logged when the monitored
sensor's data display implausibility relative to that from the
remaining sensors.
Condition for fault identification
Test condition:
The error check runs once per driving cycle once an engine
cold start is detected and provided that the barometric
pressure is above 750 mbar.
Voltage condition:
The error check runs once per driving cycle once an engine
cold start is detected and provided that the barometric
pressure is above 750 mbar.
Condition for fault memory entry
Debounce (100 ms)
Action in service
Replace pre-particulate filter exhaust-gas temperature
sensor.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none