49A2
49A2 - U0155Information saved in
DDE
Fault code
49A2 - U0155
Fault text
DDE: Message (outside temperature, 0x310): Signal(s) in
message not valid
Fault description
The diagnostic trouble code is logged when at least one
signal of the message A_TEMP_RELATIVZEIT is received
with an error value.
Condition for fault identification
Test condition:
The following conditions must be satisfied:
- The message must be active.
- Terminal 15 must be active.
The signals are transmitted every 20 ms.
The error is checked in a 100 ms time grid.
Voltage condition:
The following conditions must be satisfied:
- The message must be active.
- Terminal 15 must be active.
The signals are transmitted every 20 ms.
The error is checked in a 100 ms time grid.
Condition for fault memory entry
Debounce (6000 ms)
Action in service
Troubleshooting in transmitting control module.
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none