FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

486C

486C - P124E

Information saved in
DDE

Fault code
486C - P124E

Fault text
NOx sensor after DeNOx cat', plausibility:

Fault description
Monitoring of correction factors for NOx sensor behind
SCR converter.
The diagnostic trouble code is logged when:
- the NOx correction factor (gradient) does not lie between
800 and 1200.
- the NOx correction factor (offset) does not lie between -
200 and 200.

Condition for fault identification
Test condition:
The error check runs while the sensor is being initialized.
Voltage condition:
The error check runs while the sensor is being initialized.

Condition for fault memory entry
Debounce (500 ms)

Action in service
Replace NOx sensor behind SCR converter.

Fault effect and breakdown warning
-

Driver information
Warning light:
MIL

Service instruction
none