47FE

47FE - P2062

Information saved in
DDE

Fault code
47FE - P2062

Fault text
DDE: Reducing-agent metering valve, activation: Open
circuit

Fault description
The DDE recognizes an open-circuit error at the output
stage:
Metering module.

Condition for fault identification
Test condition:
The error check proceeds continuously according to the
programmed process grid.
Voltage condition:
The error check proceeds continuously according to the
programmed process grid.

Condition for fault memory entry
Debounce (1000 ms)

Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace metering module.

Fault effect and breakdown warning
-

Driver information
Warning light:
MIL

Service instruction
none