Manufacturer Code Charts: 4754
4754 - P2203Information saved in
DDE
Fault code
4754 - P2203
Fault text
DDE: Nitrogen oxide sensor upstream of SCR catalytic
converter, NOx range: upper physical limit exceeded
Fault description
The diagnostic trouble code is logged when the physical
NOx signal from NOx sensor 1 (before SRC catalyst) is
greater than the limit value 1650 ppm.
Condition for fault identification
Test condition:
The test routine is executed when a valid NOx signal has
been received.
Voltage condition:
The test routine is executed when a valid NOx signal has
been received.
Condition for fault memory entry
Debounce (2000 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
3. Replace NOx sensor 1 (on front side of SCR converter).
Fault effect and breakdown warning
-
Driver information
Warning light:
MIL
Service instruction
none