43E3
43E3 - P0638Information saved in
DDE
Fault code
43E3 - P0638
Fault text
DDE: Throttle-valve actuator, activation: Output stage,
overtemperature
Fault description
The DDE recognizes an over-temperature fault in the output
stage:
Throttle-valve actuator.
Condition for fault identification
Test condition:
The check frequency depends on the process sequence
control.
Voltage condition:
The check frequency depends on the process sequence
control.
Condition for fault memory entry
Debounce (50 ms)
Action in service
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling
are OK:
Replace DDE ECU.
Fault effect and breakdown warning
The error disables regeneration in the particulate filter.
Driver information
Warning light:
MIL
Service instruction