Manufacturer Code Charts: 4390
4390 - P007DInformation saved in
DDE
Fault code
4390 - P007D
Fault text
DDE: Charge-air temperature sensor, signal: Open or short
circuit to positive
Fault description
Charge-air temperature sensor monitoring. The diagnostic
trouble code is logged when the raw sensor signal (voltage)
exceeds the specified upper limit 3260 mV.
Condition for fault identification
Test condition:
The monitoring function is only implemented when no
sensor power-supply problem is logged.
Voltage condition:
The monitoring function is only implemented when no
sensor power-supply problem is logged.
Condition for fault memory entry
Debounce (150 ms)
Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace charge-air temperature sensor.
Fault effect and breakdown warning
Proceed to the nearest BMW Service facility.
Driver information
Warning light:
MIL
Service instruction
none