FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

435A

435A - P0182

Information saved in
DDE

Fault code
435A - P0182

Fault text
DDE: Fuel-temperature sensor, range: upper physical limit
exceeded

Fault description
The diagnostic trouble code is logged when the physical
sensor signal for fuel temperature rises above the limit value
100 �C.

Condition for fault identification
Test condition:
The monitoring routine is executed only provided that no
electrical errors have been logged. The error check proceeds
continuously in the programmed process grid.
Voltage condition:
The monitoring routine is executed only provided that no
electrical errors have been logged. The error check proceeds
continuously in the programmed process grid.

Condition for fault memory entry
Debounce (4000 ms)

Action in service
1. Check wires and plug connections.
2. If wiring and plug connections are OK:
Replace fuel pressure and temperature sensor (on vehicles
without closed-loop control of low-pressure fuel-delivery
circuit: fuel-temperature sensor).

Fault effect and breakdown warning
Proceed to the nearest BMW Service facility.

Driver information
Warning light:
MIL

Service instruction
none