64 11 829 Replacing Actuator Drive of Ventilation Flaps
64 11 829 Replacing Actuator Drive Of Ventilation Flaps
Necessary preliminary tasks:
- Remove right glovebox with housing
Unfasten plug connection (1) and disconnect.
Unfasten screws (2).
Detach servodrive for ventilation flaps (3) in direction of arrow from heater/air conditioner (4).
Installation:
Place servodrive for ventilation flaps (3) over guide pin (5).
Replacement:
Servomotors must be re-addressed in the event of replacement.
Addressing can only be carried out with the BMW diagnosis system.
Service functions:
- Body
- Heating and A/C function
- Flap motors
- Re-address flap motors