Action In Service - None
2A98 - P0016Information saved in
DME
Fault code
2A98 - P0016
Fault text
Crankshaft - inlet camshaft, correlation
Fault description
Crankshaft Position - Camshaft Position Correlation (Bank 1
Sensor A)
Condition for fault identification
Test condition:
NW signal position detection monitor.
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
On every camshaft flank when the flank was outside
tolerance. Following successful synchronization.
Action in service
none
Fault effect and breakdown warning
Driver information
Warning light:
NO
Service instruction
none